Or you could use the 30 amp receptacle and 50 amp breaker, be careful and hope for the best. Conversely you could put a 50 amp cord end on your brewing equipment and use a 50 amp receptacle. As said above the correct thing to do here would be to put a thirty amp circuit breaker upstream from the 30 amp receptacle. Codes are an attempt to reduce the opportunity for unlikely things to happen. The person moving in might have an electric range and find it easier to get a plug that fits the receptacle you left in the wall and put it on the end of the range cord rather than replace the receptacle with a proper one. Codes are not written so much for situations where people know what they are doing but for what people might unknowingly do.įor example, you might leave this in this condition and move to a new house.

#50 AMP BREAKER CODE#

If you know the equipment you are using and will not be drawing more than 30 amps through the receptacle it will work but it will not be a code compliant installation. If you did that it would over heat the receptacle. In this case it would be possible to draw more than the thirty amps the receptacle is rated for through it. Technically any wiring device, such as a receptacle, downstream from the circuit breaker should be rated the same or higher than the breaker.